China Great China Facgtory for 55kw 75HP 8bar Silent Industrial Direct Driven Rotary Screw Air Compressor for Outdoor Use with high quality

Solution Description

Wonderful china facgtory for 55kw 75hp 8bar Silent Industrial Immediate pushed Rotary Screw Air Compressor For outdoor use 

Application :
Air compressor is basic industry tools, and as the 2nd biggest power supply-air resource providing products, is also the procedure air source with a number of uses, widely used in mining exploitation, oil drilling, iron and steel metallurgy, electric powered electricity, shipbuilding, electronics manufacturing, petroleum chemical business, light industry, machinery producing, foodstuff and drugs, transportation services, shipping and delivery docks, casting coating, vehicle sector, aerospace, army technologies, infrastructure and so on fields.
 

Characteristics: adopt twin rotor/screw air conclude for compression air.

Advantages of outdoor use screw compressor:
1. Accredited by ISO9001certificate, SGS, CE and etc..
two. With dustproof, rainproof and moisture-proof purpose, with IP55 course electrical cupboard, mostly using in humid, dust, lower temperature and vibrating discipline operate condition environment, like tunnel excavation project, bridge construction, mine mining website, coal powder transporting, railway venture and so on industries.
3. Undertake double rotor/ screw air conclude, the most advanced engineering and entire world famous brand name in creating and production, no leakage, ensure high air discharge and lower vitality use.
four. Has minimal temperature and vibration-proof kinds equipment device for choose, simple functioning, only to push “begin” swap to commence, has remote controlling of start off and cease operate.
5. Equip with the weighty load variety air consumption filter technique can shield the primary machine from abrasion.
six. With -100% capability adjustment function, can voltage stabilizing operation in accordance to the actual air use amount, specifically appropriate for employing on without having air tank problem.
seven. Clever microcomputer control program, Chinese and English language operation interface, malfunction display, alarm and machine end routinely.
8. Undertake higher high quality and entire world well-known brand of major components, like British isles APD oil filter, The usa AMOT temperature controlling valve, SCHNEIDER electric areas and etc., higher effectiveness, dependable and lengthy use lifestyle.
nine. Undertake globe well-known model of air ingestion filter, oil filter, air and oil separator, comprehend higher filtration precision, compressed air oil material beneath 3ppm, get to to international superior standard stage.

 Parameters of  our outside use screw  compressor:
Note: F stands for wind cooling method, W stands for water cooling technique. Other kind of pressure price machine can be personalized.

Sort Exhause stress (Mpa) Air displacemen (m3/min) Electrical power (Kw) Sounds (dBa) Dimensions (mm) Outlet pipe measurement Fat (Kg)
TKLS-7F .7/.8/1./1.3 one.23/1.sixteen/1.02/.86 seven.5 sixty seven 1300*1200*1100 G 1/two 420
TKLS-11F .7/.8/1./1.three one.sixty five/1.62/1.4/1.21 eleven 67 1300*1200*1100 G3/4 420
TKLS-15F .7/.8/1./1.3 2.3/2.2/2./1.eight fifteen sixty eight 1772*1300*1300 G1 550
TKLS-18F .7/.8/1./1.3 three./2.92/2.7/2.2 eighteen.5 70 1772*1300*1300 G1 590
TKLS-22F .7/.8/1./1.three 3.6/3.fifty three/3.2/2.4 22 seventy two 1772*1300*1300 G1 650
TKLS-30F .7/.8/1./1.3 five.2/5./4.5/3.five thirty 73 2060*1400*1600 G1 1/two 900
TKLS-37F .7/.8/1./1.3 six.2/6.1/5.6/4.8 37 seventy four 2060*1400*1600 G1 1/two 1050
TKLS-45F .7/.8/1./1.three 7.8/7.5/6.8/5.eight 45 seventy five 2060*1400*1600 G1 1/2 1120
TKLS-55F/W .7/.8/1./1.three 10.1/9.8/8.8/7.two fifty five 76 2360*1635*1765 DN50 2300
TKLS-75F/W .7/.8/1./1.three 13./twelve.3/11./10. 75 78 2360*1635*1765 DN50 2400
TKLS-90F/W .7/.8/1./1.3 16.3/fifteen.6/14.2/thirteen. 90 78 2360*1635*1765 DN50 2500
TKLS-110F/W .7/.8/1./1.3 20.4/twenty./19.2/17. a hundred and ten seventy eight 2800*1700*2100 DN80 3500
TKLS-132F/W .7/.8/1./1.3 23./22.1/21./eighteen.one 132 seventy eight 2800*1700*2100 DN80 3700
TKLS-160F/W .7/.8/1./1.three 27.8/27.1/25.2/21.two a hundred and sixty seventy eight 2800*1700*2100 DN80 4000
TKLS-185F/W .7/.8/1./1.3 32.5/thirty.5/27./23.6 185 78 3400*1800*2100 DN80 4600
TKLS-200F/W .7/.8/1./1.three 35./33.3/30.6/26.3 two hundred eighty 3400*1800*2100 DN100 4700
TKLS-250F/W .7/.8/1./1.three 44.1/43./38.1/35. 250 80 3600*2000*2100 DN100 5100

 

Our manufacturing facility and workshop:

Soon after revenue services for our air screw compressor item:
1. Delivering expert air compression system planning for totally free.
2. Offering our factory original machine elements at cheapest price after device income.
three. Delivering education and advice for totally free, customers can ship their personnel to our factory to discover how to operate the devices.
4. Guarantee time period: the screw major equipment is 1 year, the bearing is 1 yr.
five.There is almost no donning element of our machine goods due to the fact we adopt substantial quality good quality and renowned areas and electrical components when developing and manufacturing.

Certification and patents of our air compressor

FAQ:
Q1: Are you manufacturing unit or trade organization?  
A1: We are manufacturing facility.
Q2: Warranty phrases of your equipment? 
A2: One 12 months guarantee for the equipment and complex help according to your requirements.
Q3: Will you give some spare areas of the equipment? 
A3: Yes, of training course.
This autumn: How extended will you get to prepare generation? 
A4: 380V 50HZ we can shipping and delivery the products inside of 20 times. Other voltage we will shipping and delivery in thirty times.
Q5: Can you accept OEM orders? 
A5: Yes, with professional design team, OEM orders are highly welcome!

US $1,000-1,200
/ Set
|
1 Set

(Min. Order)

###

Lubrication Style: Lubricated
Cooling System: Air Cooling
Power Source: AC Power
Cylinder Position: Vertical
Structure Type: Closed Type
Installation Type: Stationary Type

###

Customization:

###

Type Exhause pressure (Mpa) Air displacemen (m3/min) Power (Kw) Noise (dBa) Dimensions (mm) Outlet pipe size Weight (Kg)
TKLS-7F 0.7/0.8/1.0/1.3 1.23/1.16/1.02/0.86 7.5 67 1300*1200*1100 G 1/2 420
TKLS-11F 0.7/0.8/1.0/1.3 1.65/1.62/1.4/1.21 11 67 1300*1200*1100 G3/4 420
TKLS-15F 0.7/0.8/1.0/1.3 2.3/2.2/2.0/1.8 15 68 1772*1300*1300 G1 550
TKLS-18F 0.7/0.8/1.0/1.3 3.0/2.92/2.7/2.2 18.5 70 1772*1300*1300 G1 590
TKLS-22F 0.7/0.8/1.0/1.3 3.6/3.53/3.2/2.4 22 72 1772*1300*1300 G1 650
TKLS-30F 0.7/0.8/1.0/1.3 5.2/5.0/4.5/3.5 30 73 2060*1400*1600 G1 1/2 900
TKLS-37F 0.7/0.8/1.0/1.3 6.2/6.1/5.6/4.8 37 74 2060*1400*1600 G1 1/2 1050
TKLS-45F 0.7/0.8/1.0/1.3 7.8/7.5/6.8/5.8 45 75 2060*1400*1600 G1 1/2 1120
TKLS-55F/W 0.7/0.8/1.0/1.3 10.1/9.8/8.8/7.2 55 76 2360*1635*1765 DN50 2300
TKLS-75F/W 0.7/0.8/1.0/1.3 13.0/12.3/11.0/10.0 75 78 2360*1635*1765 DN50 2400
TKLS-90F/W 0.7/0.8/1.0/1.3 16.3/15.6/14.2/13.0 90 78 2360*1635*1765 DN50 2500
TKLS-110F/W 0.7/0.8/1.0/1.3 20.4/20.0/19.2/17.0 110 78 2800*1700*2100 DN80 3500
TKLS-132F/W 0.7/0.8/1.0/1.3 23.0/22.1/21.0/18.1 132 78 2800*1700*2100 DN80 3700
TKLS-160F/W 0.7/0.8/1.0/1.3 27.8/27.1/25.2/21.2 160 78 2800*1700*2100 DN80 4000
TKLS-185F/W 0.7/0.8/1.0/1.3 32.5/30.5/27.0/23.6 185 78 3400*1800*2100 DN80 4600
TKLS-200F/W 0.7/0.8/1.0/1.3 35.0/33.3/30.6/26.3 200 80 3400*1800*2100 DN100 4700
TKLS-250F/W 0.7/0.8/1.0/1.3 44.1/43.0/38.1/35.0 250 80 3600*2000*2100 DN100 5100
US $1,000-1,200
/ Set
|
1 Set

(Min. Order)

###

Lubrication Style: Lubricated
Cooling System: Air Cooling
Power Source: AC Power
Cylinder Position: Vertical
Structure Type: Closed Type
Installation Type: Stationary Type

###

Customization:

###

Type Exhause pressure (Mpa) Air displacemen (m3/min) Power (Kw) Noise (dBa) Dimensions (mm) Outlet pipe size Weight (Kg)
TKLS-7F 0.7/0.8/1.0/1.3 1.23/1.16/1.02/0.86 7.5 67 1300*1200*1100 G 1/2 420
TKLS-11F 0.7/0.8/1.0/1.3 1.65/1.62/1.4/1.21 11 67 1300*1200*1100 G3/4 420
TKLS-15F 0.7/0.8/1.0/1.3 2.3/2.2/2.0/1.8 15 68 1772*1300*1300 G1 550
TKLS-18F 0.7/0.8/1.0/1.3 3.0/2.92/2.7/2.2 18.5 70 1772*1300*1300 G1 590
TKLS-22F 0.7/0.8/1.0/1.3 3.6/3.53/3.2/2.4 22 72 1772*1300*1300 G1 650
TKLS-30F 0.7/0.8/1.0/1.3 5.2/5.0/4.5/3.5 30 73 2060*1400*1600 G1 1/2 900
TKLS-37F 0.7/0.8/1.0/1.3 6.2/6.1/5.6/4.8 37 74 2060*1400*1600 G1 1/2 1050
TKLS-45F 0.7/0.8/1.0/1.3 7.8/7.5/6.8/5.8 45 75 2060*1400*1600 G1 1/2 1120
TKLS-55F/W 0.7/0.8/1.0/1.3 10.1/9.8/8.8/7.2 55 76 2360*1635*1765 DN50 2300
TKLS-75F/W 0.7/0.8/1.0/1.3 13.0/12.3/11.0/10.0 75 78 2360*1635*1765 DN50 2400
TKLS-90F/W 0.7/0.8/1.0/1.3 16.3/15.6/14.2/13.0 90 78 2360*1635*1765 DN50 2500
TKLS-110F/W 0.7/0.8/1.0/1.3 20.4/20.0/19.2/17.0 110 78 2800*1700*2100 DN80 3500
TKLS-132F/W 0.7/0.8/1.0/1.3 23.0/22.1/21.0/18.1 132 78 2800*1700*2100 DN80 3700
TKLS-160F/W 0.7/0.8/1.0/1.3 27.8/27.1/25.2/21.2 160 78 2800*1700*2100 DN80 4000
TKLS-185F/W 0.7/0.8/1.0/1.3 32.5/30.5/27.0/23.6 185 78 3400*1800*2100 DN80 4600
TKLS-200F/W 0.7/0.8/1.0/1.3 35.0/33.3/30.6/26.3 200 80 3400*1800*2100 DN100 4700
TKLS-250F/W 0.7/0.8/1.0/1.3 44.1/43.0/38.1/35.0 250 80 3600*2000*2100 DN100 5100

Choosing the Right Air Compressor For Your Home

You will find that air compressors are indispensable tools for a variety of situations, including garages, home workshops, and basements. These tools can power a variety of tools, and each model is sized to suit the job at hand. Because air compressors have only one motor, they are lightweight, compact, and easy to handle. Using one air compressor to power several tools will also reduce the wear and tear on individual components. This article will introduce some important characteristics to look for when choosing the right air compressor for your home.

Positive displacement

A positive displacement compressor applies pressure to a fluid, whereas a centrifugal one does the opposite. A positive displacement compressor creates the desired pressure by trapping air and increasing its volume. Its discharge valve releases the high-pressure gas. These compressors are used in industrial applications and nuclear power plants. The difference between a positive and negative displacement compressor is that a positive displacement compressor can compress and release air at a consistent rate.
A positive displacement air compressor uses a reciprocating piston to compress air. This reduces the volume of the air in the compression chamber, and a discharge valve opens when the pressure reaches the desired level. These compressors are used in bicycle pumps and other pneumatic tools. Positive displacement air compressors have multiple inlet ports and have several configurations. Positive displacement air compressors have a single-acting and double-acting piston, and can be oil-lubricated or oil-free.
A positive displacement air compressor is different from a dynamic compressor. It draws air into the compression chambers and then releases the pressure when the valve is opened. Positive displacement compressors are common in industrial applications and are available in single-acting, double-acting, and oil-lubricated models. Large piston compressors have ventilated intermediate pieces and crossheads on gudgeon pins. Smaller models have permanently sealed crankcases with bearings.
air-compressor

Oil-free

Oil-free air compressors have some advantages over their oil-lubricated counterparts. They do not require lubrication oil because they are coated with Teflon. The material has one of the lowest coefficients of friction and is layered, so it slides past other layers with little effort. Because of this, oil-free compressors tend to be cheaper and still deliver comparable performance. Oil-free compressors are a good choice for industrial applications.
The life of an oil-free air compressor is significantly longer than an oil-lubricated counterpart. These models can operate up to 2,000 hours, four times longer than the average oil-lubed compressor. Oil-free compressors also have a significantly lower operating noise than their oil-lubricated counterparts. And because they don’t need oil changes, they are quieter. Some even last up to 2,000 hours.
An oil-free air compressor is a good choice if your application requires high levels of purity. Several applications require ultra-pure air, and even a drop of oil can cause product spoilage or damage to production equipment. In addition to the health risks, an oil-free air compressor reduces the costs associated with oil contamination and minimizes leaks. It also eliminates the need for oil collection, disposal, and treatment.
A typical oil-free air compressor is very efficient, requiring only about 18% of the full load horsepower. However, oil-free compressors have a higher risk of premature failure and are not recommended for large-scale industrial applications. They may also use up to 18% of the compressor’s full capacity. They may sound appealing, but you must make sure you understand the benefits of an oil-free air compressor before choosing one for your industrial applications.

Single-stage

A single-stage air compressor is designed to provide the power for a single pneumatic tool or device. These machines are generally smaller than two-stage compressors and produce less heat and energy. These machines aren’t designed for heavy-duty industries, but they are still highly effective for a variety of applications, including auto shops, gas stations, and various manufacturing plants. They can also be used in borewells, as they are suitable for small spaces with low air flow requirements.
A single-stage air compressor has one cylinder and two valves – the inlet and the delivery valves. Both of these valves function mechanically, with the inlet valve controlling torque and the delivery one controlling air pressure. Generally, single-stage compressors are powered by a gas engine, but there are also electric models available. The single-stage air compressor is the most common type of air compressor. It has a single cylinder, one piston, and one air cylinder.
The single-stage air compressors are used for small projects or personal use. A two-stage air compressor is more effective for industrial projects. Its longer air end life makes it more efficient. It is also more efficient for use in the automotive industry, where the engine has many cylinders. In general, single-stage compressors require a higher power level. The single-stage model is ideal for small projects, while a two-stage one is suitable for larger-scale arsenals.
air-compressor

CFM

The cubic foot-per-minute (CFM) of an air compressor is the output of the machine. In order to calculate the CFM level, start by looking at the compressor’s specifications. You should know how many cubic feet the unit can hold and how many pounds per square inch it can compress. Once you have these information, you can calculate the CFM. Now you can use these numbers to select an appropriate air compressor for your needs.
The most common way to increase the CFM of an air compressor is to turn the regulator down. By turning the dial down, the air compressor will produce more than 10 CFM. You can also try connecting two output valves. Make sure that the settings are adjusted properly before you begin. This will ensure that your air compressor is functioning at its maximum efficiency and lifespan. To increase the CFM of your air compressor, first check that your regulator is calibrated for the desired pressure level.
To calculate the CFM of an air compressor, first determine the tank volume of the machine. Then, multiply this volume by the time it takes to fill the tank. Then, divide the result by 60 seconds to calculate the CFM. Once you know how much air your machine can hold, you can choose a suitable air compressor. If you’re working in a confined area, you should buy a tool with a large tank.

PSI

The PSI of an air compressor is the pressure that it can output. A typical air compressor has a gauge connected to the airline at the bottom, next to it, or between the two. The gauge tells the actual pressure of the air compressor, while the cut-out pressure is determined by the manufacturer. The manufacturer recommends that you set the cut-out pressure twenty to forty PSI higher than the factory recommended pressure. If you want to set the pressure for your nail gun, you can use the cut-in and cut-out pressures on your compressor, and the tank won’t exceed this range.
The PSI of an air compressor measures the force that it can deliver, which is often in pounds per square inch. For most air tools, you need at least forty to 90 psi. In general, reciprocating air compressors work on an on/off basis. This relationship is known as the duty cycle. All air compressors are rated for a particular duty cycle, such as fifty percent on and twenty-five percent off.
The Psig of an air compressor is not free, as many people believe. The PSI of an air compressor is not free, but it is essential to maintain it for safe operations. If you’re having trouble maintaining a consistent pressure, consider turning down the PSI of your compressor by 2 psig. This will determine the critical pressure for the machine. You’ll also increase the amount of energy in the system by one percent.
air-compressor

Power source

The power source for an air compressor is crucial in its operation. Without the correct voltage and amperage, air compressors will not function properly. The power source must be close to the compressor so that it can plug into an electrical outlet. If it is too far from the outlet, the compressor may not be able to build enough pressure. When this happens, the fuse inside the air compressor will turn off to protect the user. The power source should be a safe distance from the compressor.
Most manufacturers do not specify the power source for an air compressor. Depending on the horsepower, the compressor will require approximately four amps of power. A one-horsepower compressor would draw about twelve amps. If it were powered by a typical 120-volt household supply, its motor would exceed the 15-amp breaker capacity. A larger air compressor, however, will require a separate 15-amp power source, making it impossible to use it with this type of power source.
The power source for an air compressor is typically electrical alternating current (AC) that is equivalent to the voltage on a standard wall outlet. A three-phase air compressor, on the other hand, requires a special AC supply with three electrical offset pulses. Regardless of the type of air compressor, the power source must be compatible with the incoming power service. One of the most common problems when attempting to connect an air compressor to an AC power source is undersized wire. This results in low voltage and high amperes, tripping of over-load relays and blown fuses.

China Great China Facgtory for 55kw 75HP 8bar Silent Industrial Direct Driven Rotary Screw Air Compressor for Outdoor Use     with high qualityChina Great China Facgtory for 55kw 75HP 8bar Silent Industrial Direct Driven Rotary Screw Air Compressor for Outdoor Use     with high quality
editor by czh 2023-01-09

Laser compressor

As one of the laser compressor manufacturers, suppliers, and exporters of mechanical products, We offer laser compressor and many other products.

Please get in touch with us for details.

Manufacturer supplier exporter of laser compressor.

Recent Posts